Vista de pagina 5
Offline Array Recovery ProceduresSuperTrak SX6000 and UltraTrak, Version 5a
6 of 34
SuperBuild Array Utility 1.10 (c) 2001 Promise Technology, Inc.
[ Define Array Definition Menu ]
Array No RAID Level Total Drv Status
Array 1 RAID 5 3 Critical
Stripe Block: 64 KB Initialize Array: ON Gigabyte Boundary: ON
[ Drive Assignments ]
Channel ID Drive Model Capacity (MB) Assignment
1:Master MAXTOR87000A8 61234 Array 1
2:Master MAXTOR87000A8 61234 Array 1
? : ? failed or disconnected
[ Keys Available ]
[ ] Up [ ] Down [Space] Change Option [ESC] Exit [Ctrl-Y] Save
The Define Array Definition Menu confirms that this three-drive array has lost a drive. If
you know which channel the failed drive was on, remove the disk drive for testing.
Remove a Disk Drive for Testing
The most important part of testing a suspect disk drive is to identify the right one.
135
2
4
6
The photo above shows a SuperTrak SX6000 card in a typical installation, with the
channel numbers indicated. Identify the channel with the failed drive then follow the
drive cable to that drive.
1. Shut down the computer and open the case.
2. Find the channel on the SuperTrak card corresponding to the failed drive.
3. Follow the drive cable to the failed drive then disconnect the drive from its cables.
Vista de pagina 5