Promise Technology SuperTrak SX6000 Manual de usuario Pagina 25

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 34
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 24
Offline Array Recovery ProceduresSuperTrak SX6000 and UltraTrak, Version 5a
25 of 34
SuperBuild Array Utility 1.10 (c) 2001 Promise Technology, Inc.
[ Define Array Definition Menu ]
Array No RAID Level Total Drv Status
Array 1 RAID 5 3 Offline
Stripe Block: 64 KB Initialize Array: ON Gigabyte Boundary: ON
[ Drive Assignments ]
Channel ID Drive Model Capacity (MB) Assignment
1:Master MAXTOR87000A8 61234 Array 1
2:Master MAXTOR87000A8 61234 Array 1
3:Master MAXTOR87000A8 61234 Array 1
4:Master MAXTOR87000A8 ---- ----
5:Master MAXTOR87000A8 ---- ----
6:Master MAXTOR87000A8 ---- ----
[ Keys Available ]
[ ] Up [ ] Down [Space] Change Option [ESC] Exit [Ctrl-Y] Save
5. This screen tells you the RAID Level, Stripe Block Size and Gigabyte Boundary.
Record the values so you will have them to create the new array. Press Esc twice to