Offline Array Recovery Procedures—SuperTrak SX6000 and UltraTrak, Version 5a
21 of 34
Case 5: Array goes OFFLINE because the wrong disk was
removed from a
CRITICAL array.
Warning
Do NOT replace the removed disk while the system is running.
1. Turn off the UltraTrak or SuperTrak PC.
2. Replace the removed disk. Keep the disks in their original order.
3. Reboot the UltraTrak or SuperTrak PC. The array will be restored to its previous
status.
Important
If the array goes OFFLINE rather showing its previous status, follow these
steps:
a. Shut down the system.
b. Boot (turn on) the SuperTrak PC or the UltraTrak.
c. Delete the existing array and create a new one.
Warning: This procedure may result in data loss. Follow instructions
carefully.
Refer to the sections SuperTrak BIOS Recovery Procedure on 23, or
UltraTrak Recovery Procedure on page 29, for step-by-step instructions.
d. Reboot the system. Array status will be FUNCTIONAL.
Comentarios a estos manuales