Offline Array Recovery ProceduresSuperTrak SX6000 and UltraTrak, Version 5a
17 of 34
Recovery Procedure for Case 2
Warning
This procedure may result in data loss. Follow instructions carefully. Be
sure you have a backup copy of all your data from the array before
beginning the procedure.
UltraTrak users, see Alternative Recovery Procedure for Case 2 on the next
page.
1. Use PAM to find the disk with the bad sector. Right click on the
Controller icon and select Read Events from the popup menu
(right). The Event Viewer appears (below).
2. Remove the disk drive with the bad sector and run a diagnostic test on it. If the test
verifies the bad sector, replace the drive.
3. Make sure all the disks, including the target disk, are in the cabinet (UltraTrak) or
connected (SuperTrak) in their original order.
4. Boot the SuperTrak PC or UltraTrak.
5. Delete the existing array and create a new one.
Refer to the sections SuperTrak BIOS Recovery Procedure on page 23, or UltraTrak
Recovery Procedure on page 29, for step-by-step instructions.
In this case, you may leave the Initialization option on or enabled, since the data has
already been saved off the array.
6. Transfer your data onto the new array. This completes the procedure.