In order to run the Transition function:
The spare drive in the rebuild array must be revertible
The replacement drive must be unconfigured, meaning it cannot be part of
an array nor assigned as a revertible spare
The replacement drive must have the same or larger capacity as the drive it
replaces
You make a spare drive revertible when you create it. The spare drive can be
global or dedicated. To create a revertible spare drive, see “Create Spare Drive”
on page 146 or “Create New Spare Drive” on page 196.
To run Transition in the CLU, see “Disk Array Settings and Functions” on
page 179.
To run Transition in WebPAM PROe, see “Transition” on page 137.