Promise Technology SuperTrack EX8658 Manual de usuario Pagina 282

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 324
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 281
SuperTrak EX Series User Manual
268
Figure 3. Physical Drive Management screen
In the example above, there is no physical drive for ID 3. Assuming you
installed a physical drive onto Channel 3 of the SuperTrak controller, this is
the failed physical drive.
3. Shut down the Host PC, open the case, check the power and data
connections to each physical drive, correct any shortcomings, restart the
Host PC and check in SuperBuild again.
Finding the Failed Drive in WebPAM PRO
To locate a failed or missing physical drive:
1. Open WebPAM PRO.
See “Logging into WebPAM PRO” on
page 109 for more information.
2. Click the Subsystem icon in Tree View.
3. Click the Enclosures icon.
4. Click the Enclosure icon.
5. Click the Physical Drives icon.
6. Examine the list of physical drives.
If a drive was present but is now
missing, that is the failed drive. Check
the power and data connections. If
those are OK, you must replace the
drive.
If a drive is marked as PFA or Stale, that
is the problem drive and you might be
able to salvage the drive.
If a drive is marked as Offline or Dead,
that is the problem drive and you must replace it.
ID 3 is missing
Vista de pagina 281
1 2 ... 277 278 279 280 281 282 283 284 285 286 287 ... 323 324

Comentarios a estos manuales

Sin comentarios