Promise Technology SuperTrack EX8658 Manual de usuario Pagina 251

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 324
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 250
Chapter 7: Technology Background
237
RAID 60 – Striping of Double Parity
RAID 60 combines both RAID 6 and RAID 0 features. Data is striped across
disks as in RAID 0, and it uses double distributed parity as in RAID 6. RAID 60
provides data reliability, good overall performance and supports larger volume
sizes.
Figure 8. RAID 60 is a combination of RAID 6 and RAID 0
The total capacity of a RAID 60 logical drive is the smallest physical drive times
the number of physical drives, minus four.
RAID 60 also provides very high reliability because data is still available even if
multiple physical drives fail (two in each axle). The greater the number of axles,
the greater the number of physical drives that can fail without the RAID 60 logical
drive going offline.
Component Minimum Maximum
Number of Axles 2 16
Physical Drives per Axle 4 16
Physical Drives per Logical Drive 8 256
Data
Stripes
Double Distributed Parity
Physical drives
Axle 1
Axle 2
Vista de pagina 250