Promise Technology E610f Manual Pagina 298

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 436
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 297
VTrak E-Class Product Manual
276
RAID 0
A RAID 0 source logical drive can migrate to the following target logical drives:
Target Requirements
RAID 0 Add physical drives.
RAID 1 2 physical drives only.
Only a single-drive RAID 0 can migrate to RAID 1 by adding 1
physical drive.
RAID 1E 3 or more physical drives.
If existing physical drives have no unused space, add 1 or
more physical drives.
RAID 5 3 physical drives minimum, 32 maximum.
RAID 0 must have less than 16 physical drives.
If existing physical drives have no unused space, add 1 or
more physical drives.
RAID 6 4 physical drives minimum, 32 maximum.
If existing physical drives have no unused space, add 1 or
more physical drives.
RAID 10 4 physical drives minimum.
Even number of physical drives.
If existing physical drives have no unused space, add 1 or
more physical drives.
RAID 50 6 physical drives minimum, 32 per axle maximum.
If existing physical drives have no unused space, add 1 or
more physical drives.
RAID 60 8 physical drives minimum, 32 per axle maximum.
If existing physical drives have no unused space, add 1 or
more physical drives.
Vista de pagina 297
1 2 ... 293 294 295 296 297 298 299 300 301 302 303 ... 435 436

Comentarios a estos manuales

Sin comentarios