Promise Technology VessRAID 1000s Series Manual Pagina 378

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 462
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 377
VessRAID 1000f, 1000i, 1000s Product Manual
358
RAID 50
A RAID 50 Source logical drive can migrate to the following Target logical drives:
RAID 60
A RAID 60 Source logical drive can migrate to the following Target logical drives:
Target Requirements
RAID 0 None.
RAID 1E None.
RAID 3
RAID 5
32 physical drives maximum.
RAID 50 must have less than 32 physical drives.
RAID 6 32 physical drives maximum.
RAID 50 must have less than 32 physical drives.
If existing physical drives have no unused space, add 1 or
more physical drives.
RAID 10 Even number of physical drives.
RAID 30 6 physical drives minimum, 32 per axle maximum.
If existing physical drives have no unused space, add 1 or
more physical drives.
RAID 50 Add physical drives. 32 per axle maximum.
RAID 60 8 physical drives minimum, 32 per axle maximum.
If existing physical drives have no unused space, add 1 or
more physical drives.
Target Requirements
RAID 6 16 physical drives maximum.
RAID 60 must have less than 32 physical drives.
If existing physical drives have no unused space, add 1 or
more physical drives.
RAID 60 Add physical drives. 32 per axle maximum.
Vista de pagina 377
1 2 ... 373 374 375 376 377 378 379 380 381 382 383 ... 461 462

Comentarios a estos manuales

Sin comentarios