Promise Technology VessRAID 1000s Series Manual Pagina 374

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 462
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 373
VessRAID 1000f, 1000i, 1000s Product Manual
354
RAID 3
A RAID 3 Source logical drive can migrate to the following Target logical drives:
Target Requirements
RAID 0 None.
RAID 1E None.
RAID 3 Add physical drives. 32 maximum.
RAID 5 3 physical drives minimum, 32 maximum.
If existing physical drives have no unused space, add 1 or
more physical drives.
RAID 6 4 physical drives minimum, 32 maximum.
If existing physical drives have no unused space, add 1 or
more physical drives.
RAID 10 4 physical drives minimum.
Even number of physical drives.
If existing physical drives have no unused space, add 1 or
more physical drives.
RAID 30
RAID 50
6 physical drives minimum, 32 per axle maximum.
If existing physical drives have no unused space, add 1 or
more physical drives.
RAID 50 6 physical drives minimum, 32 per axle maximum.
If existing physical drives have no unused space, add 1 or
more physical drives.
RAID 60 8 physical drives minimum, 32 per axle maximum.
If existing physical drives have no unused space, add 1 or
more physical drives.
Vista de pagina 373
1 2 ... 369 370 371 372 373 374 375 376 377 378 379 ... 461 462

Comentarios a estos manuales

Sin comentarios