VessRAID 1000s Series Product Manual
186
Flashing through TFTP
See “Chapter 7: Maintenance” on page 219 for instructions.
Viewing Flash Image Information
Flash image information refers to the package of firmware components running
on your VessRAID controller, including:
Component name
Version number
•Build date
Flash (installation) date
To view flash image information:
1. From the Main Menu, highlight Additional Info and Management, and press
Enter.
2. Highlight Flash Image Version Info and press Enter.
The flash image information displays on the screen.
Running Image Info – The firmware package currently running on the
controllers
Flashed Image Info – The firmware package flashed to memory
If the Running and Flashed Images do not match, the VessRAID has not
restarted since the firmware was last updated. Restart the VessRAID to run the
Flashed firmware package. See “Restarting the Subsystem” on page 191.
Note that all of these components are upgraded together in a package. See
“Updating the Firmware in the CLU” on page 222.
Clearing Statistics
This function clears the statistical counts for the RAID controller, SAS ports,
physical drives, and logical drives.
To clear statistics:
1. From the Main Menu, highlight Additional Info and Management and press
Enter.
2. Highlight Clear Statistics and press Enter.
3. Press Y to confirm the deletion.