Managing UPS Units
Uninterruptible Power Supply (UPS) Management includes the following
functions:
Viewing a List of UPS Units (below)
Making UPS Settings (page 103)
Viewing UPS Information (page 104)
Viewing a List of UPS Units
To view a list of UPS units supporting the VessRAID:
1. Click the Subsystem icon in Tree View.
2. Click the UPS icon.
3. Click the Information tab in Management View.
Information in the UPS List includes:
UPS ID – Click the ID number to view the UPS Tab.
Operational Status – OK means Normal.
On AC means the UPS is connected to a viable external AC power
source.
On Battery means the external AC power source is offline and the UPS
is running on battery power.
Model Name or Number
Battery Capacity – Backup capacity expressed as a percentage.
Loading Ratio – Actual output of UPS as a percentage of the rated
output. See the Note below.
Remaining Backup Time – Number of minutes the UPS is expected to
power your system in the event of a power failure.
Note
The maximum recommended Loading Ratio varies among models
of UPS units. The general range is 60% to 80%. If the reported
Loading Ratio exceeds the recommended value for your UPS unit:
Have fewer subsystems or peripherals connected to this UPS
unit.
Add more UPS units, or use a higher-capacity UPS unit, to
protect your RAID systems.