Promise Technology VessRAID 1000s Series Manual Pagina 190

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 340
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 189
VessRAID 1000s Series Product Manual
174
Managing UPS Units
Uninterruptible Power Supply (UPS) Management includes the following
functions:
Viewing a List of UPS Units (below)
Making UPS Settings (page 175)
Viewing UPS Information (page 176)
Viewing a List of UPS Units
To view a list of UPS units supporting the VessRAID:
1. From the Main Menu, highlight Additional Info and Management and press
Enter.
2. Highlight UPS Management and press Enter.
Information in the UPS List includes:
UPS ID – Click the ID number to view the UPS Tab.
Operational Status – OK means Normal.
On AC means the UPS is connected to a viable external AC power
source.
On Battery means the external AC power source is offline and the UPS
is running on battery power.
Model Name or Number
Capacity – Backup capacity expressed as a percentage.
Loading – Actual output of UPS as a percentage of the rated output.
See the Note below.
Remaining Minutes – Number of minutes the UPS is expected to power
your system in the event of a power failure.
Note
The maximum recommended Loading Ratio varies among models
of UPS units. The general range is 60% to 80%. If the reported
Loading Ratio exceeds the recommended value for your UPS unit:
Have fewer subsystems or peripherals connected to this UPS
unit.
Add more UPS units, or use a higher-capacity UPS unit, to
protect your RAID systems.
Vista de pagina 189