Promise Technology VTrak J610S Manual Pagina 291

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 340
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 290
Chapter 8: Troubleshooting
277
Disk array settings have
been changed
The user successfully logical drive settings. See
page 127.
Drive Interface Controller
Drive-interface controller
found
Normal.
Drive-interface controller
is NOT found
Restart the VTrak. See page 215. If this message
appears repeatedly, contact Technical Support. See
page 305.
Drive-interface
diagnostics has passed
Normal.
Drive-interface
diagnostics has failed
Restart the VTrak. See page 215. If this message
appears repeatedly, contact Technical Support. See
page 305.
Drive-interface controller
has generated a general/
data parity error.
Drive-to-controller parity error. If this message
appears repeatedly, contact Technical Support. See
page 305.
Enclosure
Enclosure temperature is
above the threshold/
warning threshold
The VTrak is overheating. Check for airflow around
and through the VTrak, and verify that all fans are
working. Replace fans as needed.
Enclosure temperature is
above the critical
threshold
The VTrak is seriously overheating. Check for airflow
around and through the VTrak, and verify that all fans
are working. Replace fans as needed.
Enclosure temperature is
within the normal range
Normal.
Event Log
Event logging is enabled Event logging has been successfully enabled.
Event logging is disabled Event logging has been disabled.
Event log buffer is cleared
in RAM
The event log was cleared.
Event log buffer is cleared
in NVRAM
The non-volatile RAM event log was cleared.
Event log buffer is cleared
in MDD
The MDD (disk drive) event log was cleared.
Reported Event Corrective Action
Vista de pagina 290
1 2 ... 286 287 288 289 290 291 292 293 294 295 296 ... 339 340

Comentarios a estos manuales

Sin comentarios