Promise Technology E610f Manual de usuario Pagina 8

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 15
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 7
Best Practices Guide 7
Table 1. Recommended settings
Setting Value Rationale
Subsystem
Redundancy Type Active-Active Supports high availability and load balancing with VTL/SIR.
The default setting is Active-Active.
Controller
LUN Affinity Disabled Ensures compatibility with VTL/SIR.
The default setting is Disabled.
Force Read Ahead Enabled Achieves the optimal performance for multiple stream
backup/restore and deduplication.
The default setting is Disabled.
Please refer to VTrak E610f Product Manual about how to
enable it.
Adaptive Write
Back Cache
Enabled Protects the data integrity in case of Battery Backup Unit (BBU)
failure or a low battery condition.
The default setting is Enabled.
Auto Rebuild Enabled Enable Automatic Rebuild to replace bad drive or Predictive
Drive Migration (PDM) to replace a drive that is going to fail.
These actions improve data reliability by reducing or eliminating
periods of lost redundancy.
The default setting is Enabled.
SATA Physical Drive Settings
ReadAheadCache Enabled Helps to achieve the optimal performance for multiple stream
backup/restore and deduplication.
The default setting is Enabled.
Write Cache Enabled Helps to achieve the optimal performance for multiple stream
backup/restore and deduplication.
The default setting is Enabled.
Medium Error
Threshold
64 This value is the number of bad blocks tolerated before the
controller marks a physical drive as Dead. By enabling this
setting, you can identify problem drives before they fail, thereby
improving system performance and reliability.
The default setting is 0, meaning disabled.
Please refer to E610f Product Manual about how to set Medium
Error Threshold.
Also see the best practice at:
http://www.promise.com/support/support_eng1.asp,
And search for keyword “Medium Error Threshold.”
Promise recommends leaving all other settings at their factory default values.
Alert Notification
It is important to set up the alert notification on the Promise VTrak E610f external disk array subsystem, as this feature
notifies the system administrator and allows him to act accordingly in the event of any status change or failure condition.
The administrator should set up event notification either through Email or Simple Network Management Protocol
(SNMP) during the initial setup phase.
Vista de pagina 7