VTrak J610s, J310s Product Manual
34
cli>cable
CN#1 Cable Length = 1 meter
CN#2 Cable Length = 3 meter
Note the cable length change for CN2.
Enclosure Command
The Enclosure command:
Displays information about the J610s or J310s enclosure (below)
Enables you to make enclosure settings (page 36)
Information
The Enclosure command displays information about the J610s or J310s
enclosure, including:
The CLI reports information for the I/O module to which it is connected and for
the rest of the components in the J310s enclosure.
Under SAS specifications, both I/O modules are active at the same time. For
management purposes, the default primary I/O module role is Primary. If a
second I/O module is present, its role is Secondary. See the arrow below for I/O
Module Role in the display. Also see “Setting Up Data Cable Connections” on
page 20.
In a J610s or J310s unit with two I/O modules, if the primary I/O module fails or is
removed, the remaining I/O module becomes the default primary I/O module and
assumes the Primary role. If the other I/O module is repaired or replaced, it
becomes the secondary I/O module and assumes the Secondary role.
At the cli> prompt, type enclosure and press Enter.
cli> enclosure
-------------------------------------------------------------------------------------
Time Since Power Up: 1 hour 46 minutes 36 seconds
Enclosure: J310s-12Bay
Time since power-up
Enclosure type
I/O module information
PSU (power supply) status and
fan speeds
Blower status and fan speeds
Temperature sensor readings
Temperature threshold settings
Voltage sensor readings
Expander SAS addresses
Attached SAS addresses